Wavelength of 914 nm was sensitive to the SSC of satsuma mandarins

"However, it is likely that the wavelengths 650-680 nm for SSC mainly attributed to the color of bayberry juice. It is same to the sensitive wavelengths to acidity of 685-695 nm, because there is nonexistent of organic acids in this region of the spectrum. So in our research, to SSC, wavelengths 970-990 nm might be of particular importance, and to acidity, 910-925 nm were better. This found was similar to the earlier literature, such as He (1998) found a wavelength of 914 nm was sensitive to the SSC of satsuma mandarins. And near 900 nm were sensitive wavelengths corresponding to organic acid of oranges."

(Shao, Y. and He. Yong (2007) Nondestructive measurement of the internal quality of bayberry juice using Vis/NIR spectroscopy, Journal of Food Engineering, 79, 1015-1019.)

Important wavelengths can be determined from PLS regression coefficients and difference in spectra

"The wavelengths important in classifying the species of interest were determined based on PLS regression coefficients and differences in spectra."

"The regression coefficients indicating important wavelengths in the calibration model are shown in Fig. 1."


(Fengyou, J., Maghirang, E., Dowell, F. Abel, C. and Ramaswamy, S., 2007. Differentating tobacco budworm and corn earworm using near-infrared spectroscopy, Journal of Economic Entomology, Vol. 100, No. 3, 759-763.)

วันอาทิตย์ที่ 8 ธันวาคม พ.ศ. 2556

SDR > 2.5 allows for sorting into two grades

"The SDRP statistic for approximately 100 samples was typically above 2.5, which allows for sorting into two grades of sweetness."

(Golic, M.; Walsh, K.B. Robustness of calibration models based on near infrared spectroscopy for the in-line grading of stonefruit for total soluble solids content. Analytica Chimica Acta 2006, 555, 286-291.)

วันเสาร์ที่ 16 พฤศจิกายน พ.ศ. 2556

In transmission spectra of milk, low scattering gave rise to low absorbance.




"The original NIR spectra of the milk samples having high, medium and low fat contents are shown in Figure 3. The spectrum of milk shifted upward with an increase of fat content. In raw milk, the fat exists in the form of globules from 1 mm to 12 mm in diameter, which act as a scattering material. As fat content increases, the number of fat globules increases, and the scattering effect becomes more severe.”

(Chen, J.Y., Iyo, C., Terada, F. and Kawano, S. 2002. Effect of multiplicative scatter correction on wavelength selection for near infrared calibration to determine fat content in raw milk, Journal of Near Infrared Spectroscopy. 10, 301-307.)

วันพฤหัสบดีที่ 7 พฤศจิกายน พ.ศ. 2556

High resolution: is it useful for broad band NIR?

"I have to add something to what David Hopkins said: in the early days of NIR (say, from the mid-1970s to the mid-1980s) the major applications were in the agricultural areas. The absorbance bands corresponding to the key materials in those types of samples were in fact, inherently broad: moisture, starch, and protein all have absorbances that are intrinsically broad due to the effects Dave mentioned. Therefore there was little or no incentive for the instrument manufacturers to design instruments with high spectral resolution, because the applications of them, at that time, did not justify expending the engineering time and resources to improve the resolution. Nowadays, of course, many more different types of applications exist, some of which include measurements of materials with the sharp bands that Dave also described. It is the change in the measurement requirements that drove the technologies in the direction of high spectral resolution devices." (Howard Mark, http://www.impublications.com/discus/messages/5/2147.html?1163283835)

วันศุกร์ที่ 25 ตุลาคม พ.ศ. 2556

Weak absorbance in NIR region is beneficial.

"The primary advantage of the NIR region is that absorbances are lower than in neighbouring regions and generally obey the Beer/Lambert law, i.e., absorbance increases linearly with concentration. This is because NIR absorptions are generally 10-100 times weaker in intensity than the fundamental mid-IR absorption bands. The weakness of the absorptions is a benefit, providing direct analysis of samples without dilution or the requirement of short optical pathlengths or dispersion in non-absorbing matrices used in traditional sampling techniques in UV/Vis and mid-IR spectroscopies."

(http://www.pdkprojects.com/aboutnirs.html#calibration)

วันพฤหัสบดีที่ 24 ตุลาคม พ.ศ. 2556

High resolution is not necessary for NIRS (Spectral resolution less than 10 nm is sufficient)


"Averaging over wavelengths is used to reduce the number of
wavelengths or to smooth the spectrum. Modern spectrophotometers
typically have an optical resolution beyond 10 nm,
whereas a 10 nm resolution is often sufficient for most applications.
Also, most spectrophotometers provide a better spectral
resolution (often 1–2 nm) than the actual optical resolution;
while this certainly increases statistical processing time it does
not improve the information content of the spectra. Further,
below 1100 nm the bandwidth of absorption peaks is typically
larger than 40 nm (Greensill et al., 2001, and references therein).
Nicola¨ı et al. (2006a) artificially inflated NIR reflectance spectra
of apple with a 2 nm resolution tenfold to 0.2 nm resolution; arti-
ficial reflectance values between two neighbouring wavelengths
in the original spectra were obtained by linear interpolation,
and Gaussian noise was added. The accuracy of the corresponding
PLS model was very low but increased by removing
redundant high resolution information by means ofwavelet compression.
The best results were obtained with compression ratios
of 20–30, loosely corresponding to a wavelength resolution of
about 5 nm."

(Nondestructive measurement of fruit and vegetable quality
by means of NIR spectroscopy: A review
Bart M. Nicola¨ı, Katrien Beullensa, Els Bobelyna, Ann Peirs ,
Wouter Saeys , Karen I. Theron , Jeroen Lammertyna
Postharvest Biology and Technology 46 (2007) 99–118)

"Resolution is one of the measurement parameters involved in obtaining spectra with FTIR.
The resolution can be set to values such as 16 cm-1, 8 cm-1, 4 cm-1, or 2 cm-1. It indicates the degree of fineness of the data obtained by measurement (i.e., the minimum peak interval that can be distinguished). For example, if 4 cm-1 is selected, spectra will be obtained at intervals of approximately 2 cm-1. To obtain sharper spectra (i.e., spectra with a higher resolution), a value such as 2 cm-1 or 1 cm-1 is set.
In fact, although this works for gaseous samples, there are cases with solid and liquid samples where the resolution of the data obtained does not improve even if a higher resolution is set. This is because the molecules of the solid or liquid are influenced by other molecules around them, causing the actual peaks to broaden.
Also, if the resolution is increased, a smaller aperture is selected in the way described later, and the intensity of the light entering the detector is reduced, increasing the relative amount of noise in the spectra. Therefore, it is undesirable for the resolution to be increased more than necessary.
For this reason, the resolution is usually set to approximately 4 cm-1 for solid and liquid samples, and to approximately 1 cm-1 or 0.5 cm-1 for gaseous samples. On some occasions, a low resolution is set for gaseous samples if the purpose is quantification."
(http://www.shimadzu.com/an/ftir/support/tips/letter8/tech.html)