"Like other techniques, NIR spectroscopy has also some drawbacks. The low sensitivity of this technique restricts the determination of the active principles with less than 0.01% (w/w). NIR spectroscopy is an indirect method which requires a reference method, Chemometric techniques - statistical and mathematical procedures - to extract, and interpret spectral information acquired from the sample NIR spectra"
(FT-NIR spectroscopy and Laser Diffraction particle sizing of APIs in Pharmaceutical formulations
Joana Lucia Carrilho Figuriredo, Mestrado Integrado em Engenharia Quimica, Setembro de 2008)
(Celio Pasquini (2003) Near Infrared Spectroscopy: Fundamentals, Practical Aspects and Analytical Applications: J. Braz. Chem. Soc.; Vol. 14 No. 2)
วันพฤหัสบดีที่ 24 ตุลาคม พ.ศ. 2556
วันเสาร์ที่ 5 ตุลาคม พ.ศ. 2556
The reason NIR has an advantage over IR is that NIR has lower absorbance coefficients
"The reason NIR has an advantage over IR is that NIR has lower absorbance coefficients. Due to this, the optimum path length without dilution in the IR is in micrometers, where as long NIR is in millimeters and short NIR is in centimeters. This means that with NIR it is possible to measure representative sample portions with simple or no sample preparation. It is this lack of sample preparation makes this method preferred for analysis of agricultural and food materials."
(Near-Infrared Spectroscopy for Analysis of Agricultural Material Eric C. Newgard)
(Near-Infrared Spectroscopy for Analysis of Agricultural Material Eric C. Newgard)
วันเสาร์ที่ 14 กันยายน พ.ศ. 2556
Many strong peaks in Regression coefficients reflected the complexity of the calibration model
"To clarify the calibration structure, the PLS regression
coefficient plots, which are the regression coefficients
plotted against wavelength, are shown in Fig. 4. Many
strong peaks could be observed, indicating the complexity of the calibration model."
Suthiluk, P., Saranwong, S., Kawano, S., Numthuam, S., & Satake, T. (2008). Possibility of using near infrared spectroscopy for evaluation of bacterial contamination in shredded cabbage. International Journal of Food Science and Technology, 43(1), 160-165.
coefficient plots, which are the regression coefficients
plotted against wavelength, are shown in Fig. 4. Many
strong peaks could be observed, indicating the complexity of the calibration model."
Suthiluk, P., Saranwong, S., Kawano, S., Numthuam, S., & Satake, T. (2008). Possibility of using near infrared spectroscopy for evaluation of bacterial contamination in shredded cabbage. International Journal of Food Science and Technology, 43(1), 160-165.
Good argument on the difficulty to indicate which are the molecules responsible for spectral information
"By analysing the regression coefficient of the four PLS models
(Fig. 6) it can be seen that the region between 5000 and
4000 cm 1 is the most important. This spectral region is mainly
due to C–H and C–C combination bands and is the one that contains
most information regarding the chemical composition of the defective
and non-defective beans, although, as already stated, coffee is a
combination of numerous organic molecules and therefore it is difficult
to indicate which are the molecules responsible for the information
contained in the spectral region referred to previously."
(Fig. 6) it can be seen that the region between 5000 and
4000 cm 1 is the most important. This spectral region is mainly
due to C–H and C–C combination bands and is the one that contains
most information regarding the chemical composition of the defective
and non-defective beans, although, as already stated, coffee is a
combination of numerous organic molecules and therefore it is difficult
to indicate which are the molecules responsible for the information
contained in the spectral region referred to previously."
Ana Paula Craig, Adriana S. Franca, Leandro S. Oliveira, Evaluation of the potential of FTIR and chemometrics for separation between defective and non-defective coffees, Food Chemistry, Volume 132, Issue 3, 1 June 2012, Pages 1368-1374, ISSN 0308-8146,
Reference for the PLS regression
"The PLS regression model is commonly used in chemometrics
with the objective of establishing regression models (for physical
or chemical properties) from spectral data (Geladi & Kowalski,
1986; Miller, 2000)."
Geladi, P., & Kowalski, B. R. (1986). Partial least-squares regression – a tutorial.
Analytica Chimica Acta, 185, 1–17.
with the objective of establishing regression models (for physical
or chemical properties) from spectral data (Geladi & Kowalski,
1986; Miller, 2000)."
Geladi, P., & Kowalski, B. R. (1986). Partial least-squares regression – a tutorial.
Analytica Chimica Acta, 185, 1–17.
Reference for leave-one-out cross validation for the optimal number of latent variables for PLSR model
"The coffee bean qualities mass fraction values were modelled
from the NIR spectra with partial least squares (PLS) regression.
The optimal number of latent variables for each model was estimated
with the leave-one-out cross-validation method (Tormod,
Tomas, Fearn, & Tony, 2002)."
Tormod, N., Tomas, I., Fearn, T., & Tony, D. (2002). A User-Friendly Guide to
Multivariate Calibration and Classification. Chichester: NIR Publications.
from the NIR spectra with partial least squares (PLS) regression.
The optimal number of latent variables for each model was estimated
with the leave-one-out cross-validation method (Tormod,
Tomas, Fearn, & Tony, 2002)."
Tormod, N., Tomas, I., Fearn, T., & Tony, D. (2002). A User-Friendly Guide to
Multivariate Calibration and Classification. Chichester: NIR Publications.
วันจันทร์ที่ 8 กรกฎาคม พ.ศ. 2556
Either RPD or SDR is OK.
"The RPD is defined as the ratio of the standard deviation of the response variable to the RMSEP or
RMSECV (some authors use the term SDR). An RPD between 1.5 and 2 means that the model can discriminate low from high values of the response variable; a value between 2 and 2.5 indicates that coarse quantitative predictions are possible, and a value between 2.5 and 3 or above corresponds to good and
excellent prediction accuracy, respectively."
(Postharvest Biology and Technology 46 (2007) 99–118
Review
Nondestructive measurement of fruit and vegetable quality
by means of NIR spectroscopy: A review
Bart M. Nicola¨ı, Katrien Beullens, Els Bobelyn, Ann Peirs,
Wouter Saeys, Karen I. Theron, Jeroen Lammertyn)
RMSECV (some authors use the term SDR). An RPD between 1.5 and 2 means that the model can discriminate low from high values of the response variable; a value between 2 and 2.5 indicates that coarse quantitative predictions are possible, and a value between 2.5 and 3 or above corresponds to good and
excellent prediction accuracy, respectively."
(Postharvest Biology and Technology 46 (2007) 99–118
Review
Nondestructive measurement of fruit and vegetable quality
by means of NIR spectroscopy: A review
Bart M. Nicola¨ı, Katrien Beullens, Els Bobelyn, Ann Peirs,
Wouter Saeys, Karen I. Theron, Jeroen Lammertyn)